Powerfactor has an excellent reputation for providing power solutions when a suitable "off the shelf " product does not exist. We are able to produce cost effective solutions in relatively low volume from our local design and development partners here in the UK. However should your project require high volume production, we can arrange for 'in-house' production in the Far East. This combines the convenience of local design and project control, with the benefits of low cost manufacturing. A powerful combination! Ask us to quote.
Some examples of our designs are shown below, please contact us if you would like to discuss your psu requirements.
![]() |
The battery monitor / controller displays the state of charge of a 12V, or 24V battery. Its 10 led's progressively 'count down' from green to red to represent fully charged to fully discharged. At a pre-determined level a relay volt free contact can be triggered to signal processors etc. |
![]() |
PowerCube - E551: Portable power for powering items such as medical respirators when patient is being transported from say bed to ambulance. It's external 'medical'
switched mode charger charges the internal battery to provide an output of
230Vac for up to 1.5hrs continuous use at 100 watts. The output
can also provide peak power
bursts up to 250 watts. |
![]() |
PF1956: This unit
delivers a constant 36 to 72Vdc output from a choice of 3 independent
input voltage sources:
90 to 264Vac, 110Vdc, or a 48V battery. Designed as a secure power supply to power pressure transducers fitted within high voltage underground cables, this unit has the ability to monitor power from 3 separate input sources, sequencing from one to the other depending on which input is present. The dc output uninterruptible supply is then divided up into a total of 17 individual outputs providing a total power of 400 watts.
|
![]() |
PF1352: 24Volt 14Amp Temperature compensated ruggedised Lead-Acid Battery
Charger. Designed for use in harsh environments.
|
![]() |
PFS105:
Dual redundant 500 watt power supply and distribution power rack
providing 12 separate 24V dc switched and fused outputs.
Features include failure alarm and hot swap power supplies.
Typical applications include:
|